Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
transmitter_variable_code_1 | 0FA0 | Index into Dynamic Variables Array- Is the first an array of addresses, whose value is identified by the Field Device Variable Code | R/W | Index | 4096 | |
transmitter_variable_code_2 | 0FA2 | Index into Dynamic Variables Array- Is the second of an array of addresses, whose value identified by the Field Device Variable Code | R/W | Index | 4096 | |
transmitter_variable_code_3 | 0FA3 | Index into Dynamic Variables Array- Is the third of an array of addresses, whose value identified by the Field Device Variable Code | R/W | Index | 4096 | |
transmitter_variable_code_4 | 0FA4 | Index into Dynamic Variables Array- Is the fourth of an array of addresses, whose value identified by the Field Device Variable Code | R/W | Index | 4096 | |
primary_variable_code | 0FD0 | PV is | Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable | R/W | Index | 128 |
secondary_variable_code | 0FD1 | SV is | Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable | R/W | Index | 128 |
tertiary_variable_code | 0FD2 | TV is | Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable | R/W | Index | 128 |
fourth_variable_code | 0FD3 | 4V is | Fourth Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Fourth Variable dynamic variable | R/W | Index | 128 |
burst_command_number | 0FFD | Burst option | Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. | W | Enum | 128 |
burst_mode_select | 0FFF | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | W | Enum | 128 |
eeprom_select | 0FAB | EEPROM select | Electrically Erasable Read Only Memory Selection- Controls the data in: EEPROM Read Only Memory / Read Only Memory. | R/W | Enum | 4096 |
flow_alarm_select | 1F83 | AO Alrm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
flow_analog_value | 1F7D | AO1 | Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes | R/W | Float | 66 |
flow_damping_value | 1F87 | PV Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
flow_lower_range_value | 1F86 | PV LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
flow_lower_sensor_limit | 1F80 | PV LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R/W | Float | 8 |
flow_minimum_span | 1F81 | PV Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R/W | Float | 32 |
flow_percent_range | 1F7E | PV % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R/W | Float | 34 |
flow_sensor_serial_number | 1F82 | PV Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
flow_upper_range_value | 1F85 | PV URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
flow_upper_sensor_limit | 1F7F | PV USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R/W | Float | 8 |
transfer_function | 1F84 | Xfer fnctn | Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. | R | Enum | 64 |
Name | ID | Label | Description | Type | Access | Class |