Name ID Label Description Type Access Class
VdW_a 4023 Van der Waals a Van der Vaals calculation factor a. Please refer to instruction manual. R/W Float 2048
VdW_b 4024 Van der Waals b Van der Vaals calculation factor b. Please refer to intruction manual. R/W Float 2048
vol_ausdehnung 401C Vol. extension Volume extension of liquids as a function of temperature. R/W Float 2048
normdichte 401D Standard density Density of medium at standard conditions for pressure and temperature. R/W Float 2048
QmaxDN 4019 QmaxDN Operation QmaxDN. Maximum actual flow of metersize. R Float 2048
Qmax 401A Qmax Maximum possible flow under operating conditions for pressure and temperature. R/W Float 2048
Qmin 401B Qmin Minimum flow at operating conditions for pressure and temperature. R/W Float 2048
impuls_faktor 403D Pulse factor Pulse factor definition. R/W Float 2048
impulsbreite 403E Pulsewidth Value for pulsewidth of pulse output. R/W Float 2048
daempfung 4041 Damping Damping of current output process value. R/W Float 2048
max_alarm 4042 Max-Alarm > Setpoint for max. alarm generation. R/W Float 2048
min_alarm 4043 Min-Alarm < Setpoint for min. alarm generation. R/W Float 2048
druck_0 4045 Pressure 0% Pressure value for 0% R/W Float 2048
druck_100 4046 Pressure 100% Pressure value for 100% R/W Float 2048
konst_temp 4049 const. Temp. Constant value for temperature. Used if temperatue measurement is not available or in off mode. R/W Float 2048
konst_druck 404A const. Pressure Constant value for pressure. Used if pressure measurement is not available or in off mode. R/W Float 2048
zeit_freq_halten 405B Frequ. hold time Time to hold last measured value if there are bad quality signals with drop outs. R/W Float 2048
abgl_Iout_4mA 4053 Adjust Iout 4 mA Adjust 4 mA current output value. R/W Float 2048
abgl_Iout_20mA 4054 Adjust Iout 20 mA Adjust 20 mA current output value. R/W Float 2048
abgl_Iin_4mA 4055 Adjust Iin 4 mA Adjust 4 mA current input value for pressure transmitter. R/W Float 2048
abgl_Iin_20mA 4056 Adjust Iin 20 mA Adjust 20 mA current input value for pressure transmitter. R/W Float 2048
k_mittel 405D Mean k-factor K-factor linearisation in off mode. Use the mean k-factor of calibration. R/W Float 2048
k1 405F k1 k-factor k1 for k-factor linearisation. Please refer to calibration protocol! R/W Float 2048
k2 4061 k2 k-factor k2 for k-factor linearisation. Please refer to calibration protocol! R/W Float 2048
k3 4063 k3 k-factor k3 for k-factor linearisation. Please refer to calibration protocol! R/W Float 2048
Name ID Label Description Type Access Class