Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
k4 | 4065 | k4 | k-factor k4 for k-factor linearisation. Please refer to calibration protocol! | R/W | Float | 2048 |
k5 | 4067 | k5 | k-factor k5 for k-factor linearisation. Please refer to calibration protocol! | R/W | Float | 2048 |
float_variable_code | 40F0 | Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input | R/W | Index | 4096 | |
units_code | 07E9 | R/W | Enum | 4096 | ||
response_code | 0096 | Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. | R/W | Enum | 4096 | |
comm_status | 0098 | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. | R/W | BitEnum | 131 | |
device_status | 0097 | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process | R/W | BitEnum | 131 | |
manufacturer_id | 0099 | Produttore | Codice identificazione produttore - Si riferisce ad un produttore specifico, solitamente il nome di una società, che è responsabile della produzione del dispositivo di campo. | R | Enum | 128 |
device_type | 009A | Model | Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer | R | Enum | 128 |
request_preambles | 009B | Num req preams | Number of Request Preambles- Number of Preambles required from the Host request by the Field Device | R | Unsigned | 128 |
universal_revision | 009C | Universal rev | Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to | R | Unsigned | 128 |
transmitter_revision | 009D | Fld dev rev | Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to | R | Unsigned | 128 |
software_revision | 009E | Software rev | Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device | R | Unsigned | 2048 |
hardware_revision | 009F | Hardware rev | Versione hardware - Versione che corrisponde all’hardware dell’elettronica del dispositivo di campo. | R | Unsigned | 2048 |
physical_signaling_code | 00AB | Physicl signl code | Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port | R | Enum | 2048 |
device_flags | 00A0 | Dev flags | Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer | R | BitEnum | 128 |
device_id | 00A1 | Dev id | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. | R | Unsigned | 128 |
polling_address | 00A2 | Poll addr | Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) | W | Unsigned | 128 |
tag | 00A3 | Tag | Tag - Testo associato all’installazione del dispositivo di campo. Questo testo può essere utilizzato dall’utente in qualsiasi modo. Un uso consigliato è come etichetta univoca per un impianto che si correla all’etichetta di un dispositivo di campo: un disegno dell’impianto o su un sistema di controllo. Questa variabile viene utilizzata anche come tipo di handle di indirizzo a livello di collegamento dati. | R/W | PackedAscii | 2048 |
message | 00A4 | Messaggio | Messaggio - Testo associato al dispositivo di campo. Questo testo può essere utilizzato dall’utente in qualsiasi modo. Non esiste un uso raccomandato. | R/W | PackedAscii | 2048 |
descriptor | 00A5 | Descrittore | Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. | R/W | PackedAscii | 2048 |
date | 00A6 | Data | Data - Data del calendario gregoriano che viene memorizzata nel dispositivo di campo. Questa data può essere utilizzata dall’utente in qualsiasi modo. Non esiste un uso specifico raccomandato. | R/W | HartDate | 2048 |
write_protect | 00A7 | Write protect | Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. | R | Enum | 2048 |
private_label_distributor | 00A8 | Distributore | Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers | R | Enum | 2048 |
final_assembly_number | 00A9 | Final asmbly num | Numero di gruppo finale - Numero che viene utilizzato a scopo di identificazione ed è associato al dispositivo di campo complessivo. | R/W | Unsigned | 2048 |
transmitter_variable_code_1 | 0FA0 | Index into Dynamic Variables Array- Is the first an array of addresses, whose value is identified by the Field Device Variable Code | R/W | Index | 4096 | |
transmitter_variable_code_2 | 0FA2 | Index into Dynamic Variables Array- Is the second of an array of addresses, whose value identified by the Field Device Variable Code | R/W | Index | 4096 | |
transmitter_variable_code_3 | 0FA3 | Index into Dynamic Variables Array- Is the third of an array of addresses, whose value identified by the Field Device Variable Code | R/W | Index | 4096 | |
transmitter_variable_code_4 | 0FA4 | Index into Dynamic Variables Array- Is the fourth of an array of addresses, whose value identified by the Field Device Variable Code | R/W | Index | 4096 | |
primary_variable_code | 0FD0 | PV is | Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable | R/W | Index | 128 |
secondary_variable_code | 0FD1 | SV is | Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable | R/W | Index | 128 |
tertiary_variable_code | 0FD2 | TV is | Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable | R/W | Index | 128 |
fourth_variable_code | 0FD3 | 4V is | Fourth Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Fourth Variable dynamic variable | R/W | Index | 128 |
burst_command_number | 0FFD | Burst option | Opzione burst - Consente di selezionare le variabili che verranno sottoposte a trasferimento burst se è abilitata la modalità burst. | W | Enum | 128 |
burst_mode_select | 0FFF | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | W | Enum | 128 |
eeprom_select | 0FAB | Selezione EEPROM | Selezione EEPROM - Consente di controllare i dati in: memoria di sola lettura EEPROM/memoria di sola lettura. | R/W | Enum | 4096 |
flow_alarm_select | 1F83 | AO Alrm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
flow_analog_value | 1F7D | AO1 | Valore uscita analogica - Valore che traccia la rappresentazione del valore digitale, sotto le modalità operative normali | R/W | Float | 66 |
flow_damping_value | 1F87 | PV Damp | Valore di smorzamento - Costante di tempo di smorzamento applicata sia alla rappresentazione del valore digitale che al valore analogico della rispettiva uscita analogica. Le unità di questa variabile sono sempre in secondi. | R/W | Float | 32 |
flow_lower_range_value | 1F86 | PV LRV | Valore di campo inferiore - Definisce il punto finale operativo da cui si ricava il valore analogico e il punto 0% del campo percentuale. Inoltre, il valore di campo inferiore definisce un punto finale operativo da cui derivano gli allarmi associati al valore analogico e gli allarmi associati alla rappresentazione del valore digitale. | R/W | Float | 32 |
flow_lower_sensor_limit | 1F80 | PV LSL | Valore limite sensore inferiore - Definisce il valore minimo utilizzabile per il valore di campo inferiore. | R/W | Float | 8 |
flow_minimum_span | 1F81 | PV Min span | Valore intervallo minimo - Definisce la differenza più piccola consentita tra il valore di campo superiore e il valore di campo inferiore. | R/W | Float | 32 |
flow_percent_range | 1F7E | PV % rnge | Percentuale di campo - Variabile che traccia la rappresentazione del valore digitale rispetto al campo definito dal valore di campo inferiore e dal valore di campo superiore, per le modalità operative normali. Le unità di questa variabile sono sempre in percentuale. | R/W | Float | 34 |
flow_sensor_serial_number | 1F82 | PV Snsr s/n | Numero di serie sensore - Identifica in modo univoco il sensore da cui deriva principalmente la rappresentazione del valore digitale o la variabile dispositivo di campo. | R/W | Unsigned | 2048 |
flow_upper_range_value | 1F85 | PV URV | Valore di campo superiore - Definisce il punto finale operativo da cui deriva il valore analogico e il punto 100% del campo percentuale. Inoltre, il valore di campo superiore definisce un punto finale operativo da cui derivano gli allarmi associati al valore analogico e gli allarmi associati alla rappresentazione del valore digitale. | R/W | Float | 32 |
flow_upper_sensor_limit | 1F7F | PV USL | Valore limite sensore superiore - Definisce il valore massimo utilizzabile per il valore di campo superiore. | R/W | Float | 8 |
transfer_function | 1F84 | Xfer fnctn | Funzione trasferimento - Definisce la funzione di trasformazione che sarà applicata dalla variabile del dispositivo di campo all’uscita analogica e al campo percentuale. La funzione di trasferimento non influisce sulla rappresentazione del valore digitale. | R | Enum | 64 |
Name | ID | Label | Description | Type | Access | Class |