Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
secondary_variable_code | 0FD1 | SV is | Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable | R/W | Index | 128 |
tertiary_variable_code | 0FD2 | TV is | Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable | R/W | Index | 128 |
fourth_variable_code | 0FD3 | 4V is | Fourth Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Fourth Variable dynamic variable | R/W | Index | 128 |
burst_command_number | 0FFD | Burst option | Opción de ráfaga: Selecciona las variables a las que se aplicarán ráfagas si el modo de ráfaga está activado. | W | Enum | 128 |
burst_mode_select | 0FFF | Burst mode | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | W | Enum | 128 |
eeprom_select | 0FAB | Selección EEPROM | Selección de memoria de solo lectura borrable eléctricamente: Controla los datos de: Memoria EEPROM de solo lectura/Memoria de solo lectura. | R/W | Enum | 4096 |
flow_alarm_select | 1F83 | AO Alrm typ | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
flow_analog_value | 1F7D | AO1 | Valor de salida analógica: Valor que sigue la representación del valor digital, bajo modos de funcionamiento normales | R/W | Float | 66 |
flow_damping_value | 1F87 | PV Damp | Valor de amortiguación: Constante de tiempo de amortiguación que se aplica a la representación del valor digital y al valor analógico de la respectiva salida analógica. Las unidades de esta variable siempre se indican en segundos. | R/W | Float | 32 |
flow_lower_range_value | 1F86 | PV LRV | Valor de rango inferior: Define el punto final de funcionamiento del que se derivan el valor analógico, y el punto 0% del rango de porcentaje. Además, el valor de rango inferior define un punto final de funcionamiento del que se derivan las alarmas asociadas al valor analógico y las alarmas asociadas a la representación del valor digital. | R/W | Float | 32 |
Name | ID | Label | Description | Type | Access | Class |