Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
fehler_9 | 4052 | Error 9 | Error 9 definition. Please refer to the instruction manual! | R/W | Enum | 2048 |
k_linearisierung | 405C | k-linearisation | Kind and number of points for k-factor linearisation | R/W | Enum | 2048 |
einheit_Qv | 4033 | Unit Qv | Seletable units for actual flow Qv. | R/W | Enum | 2048 |
einheit_Qm | 4034 | Unit Qm | Selectable units for massflow Qm. | R/W | Enum | 2048 |
einheit_Zv | 4035 | Unit Zv | Selectable units for actual flow totalizer Zv. | R/W | Enum | 2048 |
einheit_Zm | 4036 | Unit Zm | Selectable units for massflow totalizer Zm. | R/W | Enum | 2048 |
einheit_dichte | 4037 | Unit density | Selectable units for density value. | R/W | Enum | 2048 |
einheit_k_faktor | 4038 | Unit k-factor | Selectable units for k-factor values. | R/W | Enum | 2048 |
einheit_temp | 4039 | Unit temp. | Selectable units for temperature value. | R/W | Enum | 2048 |
einheit_druck | 403A | Unit pressure | Selectable units for pressure value. | R/W | Enum | 2048 |
unsigned_char_variable_code | 40BF | Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input | R/W | Index | 4096 | |
ueberlauf | 403B | Overflow | Totalizer overflow counter. Please refer to the instruction manual! | R | Unsigned | 2048 |
min_frequenz | 4059 | Min. frequency | Minimum frequency value to interpreated as a flow signal. | R/W | Unsigned | 2048 |
max_frequenz | 405A | Max. frequency | Maximum frequency value to be interpreated as a flow signal. | R/W | Unsigned | 2048 |
geraeteadresse | 40C5 | Instrument address | Instrument address for communication. | R/W | Unsigned | 2048 |
netzausfall | 404E | Mains interrupts | Number of power supply interuptions since startup. | R/W | Unsigned | 2048 |
kodenummer | 404F | F&P service no. | Code number to get access to factory settings. | R/W | Unsigned | 2048 |
geraetenummer | 4015 | Instrument no. | Production number of this instrument. | R/W | Unsigned | 2048 |
f1 | 405E | f1 | Frequency f1 for k-factor linearisation. Please refer to calibration protocol! | R/W | Unsigned | 2048 |
f2 | 4060 | f2 | Frequency f2 for k-factor linearisation. Please refer to calibration protocol! | R/W | Unsigned | 2048 |
f3 | 4062 | f3 | Frequency f3 for k-factor linearisation. Please refer to calibration protocol! | R/W | Unsigned | 2048 |
f4 | 4064 | f4 | Frequency f4 for k-factor linearisation. Please refer to calibration protocol! | R/W | Unsigned | 2048 |
f5 | 4066 | f5 | Frequency f5 for k-factor linearisation. Please refer to calibration protocol! | R/W | Unsigned | 2048 |
unsigned_int_variable_code | 40D0 | Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input | R/W | Index | 4096 | |
ausgleichskoeff | 4021 | Correction factor | Correction factor for gases. Please refer to instruction manual. | R/W | Float | 2048 |
VdW_a | 4023 | Van der Waals a | Van der Vaals calculation factor a. Please refer to instruction manual. | R/W | Float | 2048 |
VdW_b | 4024 | Van der Waals b | Van der Vaals calculation factor b. Please refer to intruction manual. | R/W | Float | 2048 |
vol_ausdehnung | 401C | Vol. extension | Volume extension of liquids as a function of temperature. | R/W | Float | 2048 |
normdichte | 401D | Standard density | Density of medium at standard conditions for pressure and temperature. | R/W | Float | 2048 |
QmaxDN | 4019 | QmaxDN Operation | QmaxDN. Maximum actual flow of metersize. | R | Float | 2048 |
Qmax | 401A | Qmax | Maximum possible flow under operating conditions for pressure and temperature. | R/W | Float | 2048 |
Qmin | 401B | Qmin | Minimum flow at operating conditions for pressure and temperature. | R/W | Float | 2048 |
impuls_faktor | 403D | Pulse factor | Pulse factor definition. | R/W | Float | 2048 |
impulsbreite | 403E | Pulsewidth | Value for pulsewidth of pulse output. | R/W | Float | 2048 |
daempfung | 4041 | Damping | Damping of current output process value. | R/W | Float | 2048 |
max_alarm | 4042 | Max-Alarm > | Setpoint for max. alarm generation. | R/W | Float | 2048 |
min_alarm | 4043 | Min-Alarm < | Setpoint for min. alarm generation. | R/W | Float | 2048 |
druck_0 | 4045 | Pressure 0% | Pressure value for 0% | R/W | Float | 2048 |
druck_100 | 4046 | Pressure 100% | Pressure value for 100% | R/W | Float | 2048 |
konst_temp | 4049 | const. Temp. | Constant value for temperature. Used if temperatue measurement is not available or in off mode. | R/W | Float | 2048 |
konst_druck | 404A | const. Pressure | Constant value for pressure. Used if pressure measurement is not available or in off mode. | R/W | Float | 2048 |
zeit_freq_halten | 405B | Frequ. hold time | Time to hold last measured value if there are bad quality signals with drop outs. | R/W | Float | 2048 |
abgl_Iout_4mA | 4053 | Adjust Iout 4 mA | Adjust 4 mA current output value. | R/W | Float | 2048 |
abgl_Iout_20mA | 4054 | Adjust Iout 20 mA | Adjust 20 mA current output value. | R/W | Float | 2048 |
abgl_Iin_4mA | 4055 | Adjust Iin 4 mA | Adjust 4 mA current input value for pressure transmitter. | R/W | Float | 2048 |
abgl_Iin_20mA | 4056 | Adjust Iin 20 mA | Adjust 20 mA current input value for pressure transmitter. | R/W | Float | 2048 |
k_mittel | 405D | Mean k-factor | K-factor linearisation in off mode. Use the mean k-factor of calibration. | R/W | Float | 2048 |
k1 | 405F | k1 | k-factor k1 for k-factor linearisation. Please refer to calibration protocol! | R/W | Float | 2048 |
k2 | 4061 | k2 | k-factor k2 for k-factor linearisation. Please refer to calibration protocol! | R/W | Float | 2048 |
k3 | 4063 | k3 | k-factor k3 for k-factor linearisation. Please refer to calibration protocol! | R/W | Float | 2048 |
Name | ID | Label | Description | Type | Access | Class |