Loading…
Name ID Label Description Type Access Class
sensorFillFluid 40A9 Filling Fluid Sensor filling liquid R/W Enum 8
processConnection 40AA Process Connection Material Type of Process connction for Gauge pressure transmitters R/W Enum 8
flangeType_highSide 40AB Connection Type Type of Process connction on the side L of the Differential Transmitters R/W Enum 8
flangeMaterial_highSide 40AC Flange Material Material of the process connection of the Differential Transmitters R/W Enum 8
oringMaterial_highSide 40AD O-Ring Material Material of process wetted sealing of the Differential Transmitters R/W Enum 8
drainVentMaterial_highSide 40AE Blanking Plug Material of sealing plug of the Differential Transmitters R/W Enum 8
flangeType_lowSide 40AF Connection Type Type of Process connction on the side L of the Differential Transmitters R/W Enum 8
flangeMaterial_lowSide 40B0 Flange Material Material of the process connection of the Differential Transmitters R/W Enum 8
oringMaterial_lowSide 40B1 O-Ring Material Material of process wetted sealing of the Differential Transmitters R/W Enum 8
drainVentMaterial_lowSide 40B2 Blanking Plug Material of sealing plug of the Differential Transmitters R/W Enum 8
remoteSealNumber 40B3 Number Number of remote seal(s) R/W Enum 8
remoteSealType_highSide 40B4 Type Type of remote seal on the side H of the Sensor R/W Enum 8
remoteSealIsolatorMaterial_highSide 40B5 Diaphragm Material Material of process wetted diaphragm of the Sensor R/W Enum 8
remoteSealFillFluid_highSide 40B6 Filling Fluid Sensor filling liquid R/W Enum 8
remoteSealType_lowSide 40B7 Type Type of remote seal on the side H of the Sensor R/W Enum 8
remoteSealIsolatorMaterial_lowSide 40B8 Diaphragm Material Material of process wetted diaphragm of the Sensor R/W Enum 8
remoteSealFillFluid_lowSide 40B9 Filling Fluid Sensor filling liquid R/W Enum 8
softwareWriteProtection 40BC Soft Write Protection Software write protection R/W Enum 8
failSafeLevel 40BF Fail Safe Level Software Output fault direction between UP and DOWN R/W Enum 8
analogLow_SaturationLimit 40C1 Low Saturation Saturation limit low of the analog output current R/W Float 8
analogHigh_SaturationLimit 40C2 High Saturation Saturation limit High of the analog output current R/W Float 8
anlaog_lowAlarmValue 40C3 Low Alarm Value < 4mA during a fault. R/W Float 8
anlaog_highAlarmValue 40C4 High Alarm Value > 20mA during a fault R/W Float 8
failSafeType 40C0 Current Fail Safe Source of the Output fault between hardware and Software R Enum 2
parallelShiftValue 40C7 The current meas.value correspond to: W Float 8
Name ID Label Description Type Access Class