Name ID Label Description Type Access Class
message 00A4 Message Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. R/W PackedAscii 2048
descriptor 00A5 Descriptor Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. R/W PackedAscii 2048
date 00A6 Date Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. R/W HartDate 2048
final_assembly_number 00A9 Final Assembly Number Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device. R/W Unsigned 2048
device_specific_status_0 102B Status Group 0 Field Device Specific Status Byte 1- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
device_specific_status_1 102C Status Group 1 Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
device_specific_status_2 102D Status Group 2 Field Device Specific Status Byte 3- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
device_specific_status_3 102E Status Group 3 Field Device Specific Status Byte 4- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
device_specific_status_4 102F Status Group 4 Field Device Specific Status Byte 5- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
device_specific_status_5 1030 Status Group 5 Field Device Specific Status Byte 6- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
burst_command_number 0FFD Burst Command Hart Command to be read in Burst Mode W Enum 128
device_variable_code 1047 Device Variable Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input R/W Index 4096
primary_variable_code 0FD0 PV is Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable R/W Index 128
secondary_variable_code 0FD1 SV is Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable R/W Index 128
tertiary_variable_code 0FD2 TV is Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable R/W Index 128
quaternary_variable_code 1082 QV is Quaternary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Quaternary Variable dynamic variable R/W Index 128
loopCurrent 00ED Output Loop Current- Loop current value as perceived by the device. R/W Float 66
loop_alarm_code 00EC AO Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
percentRange 00E9 PV % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
transfer_function 1F84 Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 32
upperRange_value 00EA PV URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
lowerRange_value 00EB PV LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32