Loading…
Name ID Label Description Type Access Class
pild_band1 40FF Band Low Lower bound of the frequency range over which the signal power is computed R/W Float 8
pild_band0 4101 Band High Upper bound of the frequency range over which the signal power is computed R/W Float 8
pild_detectionTime 4102 Detection Time period of time the PILD decide for the plugging state R/W Unsigned 8
pild_maxPressureDeviation 4103 Max.Press.Deviation Max variation of the dP to maintain the last training still valid R/W Unsigned 8
pild_retrain 4104 Auto Retrain En/Dis. the automatic execution of the training R/W Enum 8
pild_trainingTime 4105 Training Time Duration of training period R/W Unsigned 8
pild_trainingRetries 4106 Training Retries Num. of training attempts if the result is not valid R/W Unsigned 8
pild_sensitivity 4107 Sensitivity PILD algorithm sensitivity R/W Enum 8
pild_bandAutoTuning 4100 Band Autotuning En/Dis. the autotune of the signal frequency band R/W Enum 8
pild_command 410A PILD Command Start/Stop PILD execution W Enum 8
Name ID Label Description Type Access Class