Loading…
Name ID Label Description Type Access Class
sv_value 4116 SV (Position) Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 10
sv_units 4117 SV Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 8
sv_classifi_code 4118 SV Classifi Code Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
sv_PDQ 4119 SV PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
sv_LS 411A SV LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
sv_FStatus 411B SV Fmly stat Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
sv_DFamily 411C SV Dev fmly Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 2048
sv_upper_limit 411D SV USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
sv_lower_limit 411E SV LSL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
sv_minimum_span 411F SV Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
Name ID Label Description Type Access Class