Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success
0x0002 Invalid selection
0x0003 Value was too high
0x0004 Value was too low
0x0005 Too few data bytes received
0x0006 Field device specific error
0x0007 In write protect mode
0x0010 Access restricted
0x0020 Busy
0x0021 Delayed response initiated
0x0022 Delayed response running
0x0023 Delayed response dead
0x0024 Delayed response conflict
0x0040 Command not implemented

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 40F5 read_engr_output
129 40F6 read_cap_temp_amp_temp_n_do
130 40F7 read_output_configuration
135 40FC read_sp_option_configuration
136 40FD read_pres_configuration
137 40FE read_sp_configuration
138 40FF read_et_configuration
139 4100 read_flow_configuration
143 41A8 read_tz_cmp_configuration
146 4104 read_digital_output_configuration
152 4109 read_disp_configuration
154 410B read_engr_unit_and_range
157 41AC read_us8_values
159 41AE read_us16_values
159 41AE read_us16_values
161 41B0 read_float_values
161 41B0 read_float_values
161 41B0 read_float_values
161 41B0 read_float_values
163 410E read_pulse_config_for_flow
170 4115 read_trim_date_and_desc
173 41B2 diag_pack
173 41B2 diag_pack
173 41B2 diag_pack
173 41B2 diag_pack
177 411B read_serial_no_and_device_info
178 411C read_soft_rev_and_device_info
179 411D read_ms_code_1
180 411E read_ms_code_2
181 411F read_ms_code_3
183 4121 read_auto_recover
185 41B3 read_si_option
187 4123 read_test_mode_data
194 4129 read_trim_who_and_loc
196 412B read_pt100_serial_no_n_device_info
210 412D read_simulate_flow_mode
212 412F read_simple_flow_calc_config
217 4131 read_fixed_ext_temp
227 41B5 read_diag_value_and_status
227 41B5 read_diag_value_and_status
227 41B5 read_diag_value_and_status
228 4134 read_model
232 4135 read_total_flow_mode
234 4137 read_total_flow
236 4139 read_total_flow_user_units
245 41B6 read_packed_ascii
248 413B read_joker_password_log
249 413C read_passwords_for_wrt_protect
252 41B8 read_optional_function_key
140 4101 read_xmtr_range_values
149 4107 read_xmtr_hl_alarm_configuration
165 4110 read_xmtr_trim_points_n_devs
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
50 1052 read_device_variable_assignments
54 1057 read_device_variable_information
105 1063 read_burst_mode_configuration
115 1254 read_event_notification_summary
512 125B read_country_code

Variable Write Command List

None