Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 PV Analog Channel Saturated
0x0008 PV Analog Channel Fixed
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 42AE read_unsigned_1byte
129 42AF read_unsigned_2byte
130 42B0 read_unsigned_4byte
133 42B1 read_signed_4byte
136 42B2 read_bit_enum_4byte
137 42B3 read_ASCII_8byte
138 42B4 read_ASCII_16byte
141 42B5 read_uint8_3byte
140 42B6 read_float
142 42BD read_device_variables_unit
143 42BE read_device_variables_specific
144 42BF read_damping_value
145 42C0 read_span_value
148 42C1 read_lowcut_value
149 42C2 read_meter_factor
150 42C3 read_calorific_config_data
151 42C4 read_line_select
152 42C5 read_adhesion_level
154 42C6 read_conductivity
156 42C7 read_diagnosis
248 42C8 Read_joker_password_log
249 42C9 Read_password_for_write_protect
155 42CC read_validity_key
153 42CD read_flow_noise_level
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
50 1052 read_device_variable_assignments
54 1057 read_device_variable_information
90 115E read_real_time_clock
105 1063 read_burst_mode_configuration
115 1254 read_event_notification_summary

Variable Write Command List

None