Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success
0x0002 Invalid selection
0x0003 Value was too high
0x0004 Value was too low
0x0005 Too few data bytes received
0x0006 Field device specific error
0x0007 In write protect mode
0x0010 Access restricted
0x0020 Busy
0x0021 Delayed response initiated
0x0022 Delayed response running
0x0023 Delayed response dead
0x0024 Delayed response conflict
0x0040 Command not implemented

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
204 4337 rcmBe32EventsDeviceSpecificStatus
180 43A3 rcmdDeviceVariableSettings
196 43A5 rcmdLocalDisplaySettings
196 43A5 rcmdLocalDisplaySettings
198 43A7 rcmdDeviceSettings
198 43A7 rcmdDeviceSettings
200 43A8 rcmParameterProtection
200 43A8 rcmParameterProtection
200 43A8 rcmParameterProtection
200 43A8 rcmParameterProtection
230 43AA rcmReadDeviceFunctionState
188 43AD rcmdIOConfiguration
190 43AE rcmdIoSettings
190 43AE rcmdIoSettings
150 43B0 rcmdConfigurationSensor
150 43B0 rcmdConfigurationSensor
150 43B0 rcmdConfigurationSensor
164 43B2 rcmdReadSensorInternalValues
164 43B2 rcmdReadSensorInternalValues
156 43B3 rcmdConversionTableInformation
158 43B5 rcmdConversionTableInformationEntry
210 43CE rcmIndSt
210 43CE rcmIndSt
210 43CE rcmIndSt
210 43CE rcmIndSt
216 43D0 rcmIndEI
216 43D0 rcmIndEI
216 43D0 rcmIndEI
216 43D0 rcmIndEI
222 43D2 rcmIndFl
224 43D4 rcmIndCol
224 43D4 rcmIndCol
224 43D4 rcmIndCol
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
50 1052 read_device_variable_assignments
54 1057 read_device_variable_information
60 0FE5 read_analog_output_and_percent_of_range
62 1062 read_analog_channels
63 104B read_analog_channel_information
70 1022 read_analog_channel_endpoint_values
76 1045 read_lock_device_state
105 1063 read_burst_mode_configuration
95 11DD read_device_communication_statistics

Variable Write Command List

None