Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label:

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R/W

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
130 4036 read_densities
131 4038 read_analog_output_direction
132 4039 read_indication
138 403A read_displacer_info
139 403B read_torque_tube_coefficient
140 403C read_existence_temp_sensor
141 403D linearity_adjustment_part_1
142 403E linearity_adjustment_part_2
143 403F read_hall_element_offset
144 4040 read_temp_sensor_compensation
145 4041 read_sensor_output
146 4042 read_error_status
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
12 00B4 read_message
13 00B5 read_tag_descriptor_date
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
16 00B8 read_final_assembly_number

Variable Write Command List

None