Loading…

Variable Name: man_pst_pressure_low_limit

Variable ID: 0x4036

Variable Label: Manual PST Actuator pressure Low Limit

Variable Help: If a measurement exceeds a high limit or goes below a low limit, warning status is activated for the device and an event is generated. Note that the measurement must remain out of the limits for the time period indicated by the latch time value.

Variable Handling: R/W

Variable Class: Diagnostic | Device

Variable Size: 4

Variable DataType: Float

Variable Display Format: |en|5.1f

Variable Edit Format: |en|5.1f

Variable Unit:

Variable Max:

Variable Min:

Variable Read Command List

Command Number Command ID Command Name
164 4698 read_online_diagnostics_limits_part2

Variable Write Command List

Command Number Command ID Command Name
131 4589 write_float_parameter