Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label:

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R/W

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
130 40EF cmd_read_measure1_info
133 40F2 cmd_read_measure1_URV_LRV
142 40F8 cmd_read_display_eng_units
150 40FA read_alarm_point
151 40FB cmd_read_relay_option
155 40FF read_relay_data
170 4102 cmd_read_time_constants
173 4105 cmd_read_gwf
180 4107 cmd_read_measurement_type
181 4108 cmd_read_rate_setup
186 410D cmd_read_measurement_urv_and_lrv
190 410F cmd_read_probe_setup
200 4113 cmd_get_analog_ouput_info
210 4119 cmd_read_alarm_command_info
220 411D cmd_read_alarm_assignment
230 411F cmd_read_echo_report_info
235 4123 cmd_read_num_report_echoes
248 4125 cmd_read_device_name_and_revision
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
12 00B4 read_message
13 00B5 read_tag_descriptor_date
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
16 00B8 read_final_assembly_number
33 0FA5 read_transmitter_variables
48 0FCE read_additional_transmitter_status

Variable Write Command List

None