Variable Name: Word_420
Variable ID: 0x40C1
Variable Label: Status Word 420
Variable Help: Reads Modbus register no. 420
Variable Handling: R
Variable Class: Dynamic | Correction
Variable Size: 2
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x0001 | Primary mA Output Saturated |
0x0002 | Secondary mA Output Saturated |
0x0004 | Primary mA Output Fixed |
0x0008 | Secondary mA Output Fixed |
0x0010 | Density Outside Limits |
0x0020 | Drive Over-Range / Partially Full Tube |
0x0040 | PIC/Daughterboard Communication Failure |
0x0080 | External Input Failure |
0x0100 | Core EEPROM Checksum Error (Config, Powerdown, Program) |
0x0200 | Core RAM Error |
0x0400 | Sensor Not Responding (No Tube Interrupt) |
0x0800 | Temperature Sensor Out-of-Range |
0x1000 | Input Over-Range |
0x2000 | Frequency Output Saturated |
0x4000 | Transmitter Not Characterized (Flocal or Sensor Type) |
0x8000 | Real-Time Interrupt Failure |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
215 | 40B2 | read_additional_diags |
Variable Write Command List
None