Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label:

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R/W

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 415A read_static_data_material_and_sensor
130 415C read_static_data_special_mass_units
131 415D read_static_data_setup_parameters
132 415E read_flocal_number
132 415E read_flocal_number
138 4163 read_pv_low_flow_cutoff
140 4165 read_static_data_special_volume_units
167 416D read_zeroing_time
170 4170 read_max_pulse_width
173 4172 read_control_output
175 4173 read_temperature_cal_factor
179 4175 read_zeroing_info
181 4176 read_fault_output
193 417C read_viscosity_info
195 417E read_specified_cutoff
197 4180 read_present_freq
198 4181 read_density_parameters
200 4183 read_alarm_parameters
203 4186 read_alarm_variable_assignment
205 4191 read_pressure_compensation_factors
207 4193 read_density_coefficient_for_high_flow
211 41D4 read_Mass_Rate_Factor
212 41D5 read_Vol_Rate_Factor
213 41D6 read_Dens_Factor
214 41D7 read_enhanced_diags
215 41D8 read_event_registers
216 41D9 read_live_zero
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
12 00B4 read_message
13 00B5 read_tag_descriptor_date
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
16 00B8 read_final_assembly_number
33 0FA5 read_transmitter_variables
48 0FCE read_additional_transmitter_status
50 0FD4 read_transmitter_variable_assignments
54 0FDA read_transmitter_variable_information
60 0FE5 read_analog_output_and_percent_of_range
61 0FE7 read_dynamic_variables_and_pv_analog_output
63 0FED read_analog_output_information
70 0FF5 read_analog_output_endpoint_values
110 1001 read_all_dynamic_variables

Variable Write Command List

None