Loading…
Loading…
Variable Name: poll_ctrl
Variable ID: 0x40B2
Variable Label: Pressure Polling
Variable Help: A variable which represents how [differential] pressure is brought into the transmitter for the purpose of viscosity calculation or pressure compensation.
Variable Handling: R/W
Variable Class: HART
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | Do not poll |
0x0001 | Visc: Poll as Primary |
0x0002 | Visc: Poll as Secondary |
0x0003 | Comp: Poll as Primary |
0x0004 | Comp: Poll as Secondary |
0x0005 | Visc: Use Analog Input |
0x0006 | Comp: Use Analog Input |
0x0007 | Visc: Modbus DNLD |
0x0008 | Comp: Modbus DNLD |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
193 | 417C | read_viscosity_info |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
192 | 417B | write_viscosity_info |