Loading…
Loading…
Variable Name: conv_lim
Variable ID: 0x40A7
Variable Label: Converg. limit
Variable Help: A unitless number that allows the user to reject the Auto Zero operation if the standard deviation is greater than 10 times the programmed convergence limit. A convergence limit of zero disables this feature.
Variable Handling: R/W
Variable Class:
Variable Size: 4
Variable DataType: Float
Variable Display Format: |en|8.2f
Variable Edit Format: |en|8.2f
Variable Unit:
Variable Max:
Variable Min:
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
167 | 416D | read_zeroing_time |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
168 | 416E | write_zeroing_time |