Loading…

Variable Name: device_specific_status_1

Variable ID: 0x102C

Variable Label: Status Group 1

Variable Help: Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Vcore out of tolerance [+/- 5%]
0x0002 3.3V Supply out of tolerance [+/- 5%]
0x0004 5V Supply out of tolerance [+/- 5%]
0x0008 1.25V Reference Out of Tolerance [+/- 5%]
0x0020 Supply voltage fault VSUPPLY
0x0040 A/D Converter error - wrong # of bytes returned/Invalid data
0x0080 Cold Start Bit Set

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 1043 read_additional_device_status

Variable Write Command List

None