Loading…

Variable Name: simulated_status_4

Variable ID: 0x483A

Variable Label: Status 4

Variable Help:

Variable Handling: R/W

Variable Class: Diagnostic

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 High Elec Temp
0x0002 Low Elec Temp
0x0004 Spare Indicator 8
0x0008 Spare Indicator 9
0x0010 Adjust Analog Outpt
0x0020 Low Supply Voltage
0x0040 Spare Indicator 10
0x0080 Weak Upr Echo

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
217 48EA read_NE107_Simulation_bytes

Variable Write Command List

Command Number Command ID Command Name
218 48EB set_NE107_Simulation_bytes