Variable Name: DielectricRange
Variable ID: 0x4686
Variable Label: Dielectric Range
Variable Help: A broad gain setting. The parameter selects the range bounding the dielectric constant of the medium being measured. Choose range 'Below 1.7' for very light hydrocarbons such as butane and propane. For stillwell applications only. Choose range '1.7 - 3' for typical hydrocarbons and oils. Choose range '3 - 10' for amines. Choose range 'Above 10' for water-based applications. If uncertain, chose lower range setting for additional signal strength. (Some ranges may not be selectable depending on the antenna model.)
Variable Handling: R/W
Variable Class:
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | Below 1.7 |
0x0001 | 1.7 - 3.0 |
0x0002 | 3 - 10 |
0x0003 | Above 10 |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
135 | 48A6 | read_DielectricRange |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
136 | 48A7 | set_DielectricRange |