Variable Name: TopBlockingDist
Variable ID: 0x470F
Variable Label: Top Blocking Dist
Variable Help: Top Blocking Distance defines an area near the antenna where reflections cannot be measured effectively due to antenna ringing. It is measured from the Sensor Reference Point. The minimum value is set by the choice of Antenna Type and is calculated as antenna length + 2 inches (50 mm); larger values are encouraged. The Level reading (and mA value) will never be higher than the value related to the Top Blocking Distance.
Variable Handling: R/W
Variable Class:
Variable Size: 4
Variable DataType: Float
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max:
Variable Min:
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
179 | 4A03 | read_TopBlockingDist |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
180 | 4A04 | set_TopBlockingDist |