Variable Name: Status_event1
Variable ID: 0x4007
Variable Label: Status
Variable Help: Describes a diagnostic event.
Variable Handling: R/W
Variable Class:
Variable Size: 2
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | OK |
0x0001 | Software Error |
0x0002 | RAM Error |
0x0003 | ADC Failure |
0x0004 | EEPROM Error |
0x0005 | Analog Board Error |
0x0006 | Analog Output Error |
0x0007 | Spare Indicator 1 |
0x0008 | Default Parameters |
0x0009 | Spare Indicator 2 |
0x000A | Sweep Time Error |
0x000B | Spare Indicator 3 |
0x000C | Too Many Echoes |
0x000D | Safety Zone Alarm |
0x000E | Echo Lost |
0x000F | Spare Indicator 4 |
0x0010 | Config Conflict |
0x0011 | High Volume Alarm |
0x0012 | High Flow Alarm |
0x0013 | Spare Indicator 5 |
0x0014 | Initializing |
0x0015 | Config Changed |
0x0016 | Spare Indicator 6 |
0x0017 | High Elec Temp |
0x0018 | Low Elec Temp |
0x0019 | Calibration Req'd |
0x001A | Reject Curve Invalid |
0x001B | Spare Indicator 7 |
0x001C | Inferred Level |
0x001D | Adjust Analog Outpt |
0x001E | Totalizer Data Lost |
0x001F | Low Supply Voltage |
0x0020 | No Moving Echo |
0x0021 | Max Jump Exceeded |
0x0022 | Low Echo Margin |
0x0023 | Hi Surface Velocity |
0x0024 | Spare Indicator 9 |
0x0025 | Sequence Record |
0x07D5 | Tank Height |
0x07D6 | Stillwell ID |
0x07D7 | Dielectric Range |
0x07D8 | Turbulence |
0x07D9 | Foam |
0x07DA | Rate of Change |
0x07DB | Sensitivity |
0x07DC | Top Blocking Dist |
0x07DD | Btm Blocking Dist |
0x07E3 | Level Trim |
0x07E5 | New User Password |
0x07E6 | NAP Value |
0x07F4 | Poll Address |
0x07FF | Lvl 4mA Set Point |
0x0800 | Vol 4mA Set Point |
0x0801 | Lvl 20mA Set Point |
0x0802 | Vol 20mA Set Point |
0x0810 | Target Selection |
0x0811 | Target Thresh Mode |
0x0812 | Target Thresh Value |
0x0813 | Target Thresh Value |
0x0814 | Base Threshold |
0x081D | # Run Average |
0x081E | Max Surface Velocity |
0x081F | Max Level Jump |
0x0821 | Echo Reject State |
0x085D | Flow 4mA Set Point |
0x085E | Flow 20mA Set Point |
0x0861 | Echo Rejection Type |
0x0862 | TVG Start Value |
0x0863 | TVG End Value |
0x0864 | TVG Start Location |
0x0865 | TVG End Location |
0x086A | Distance Threshold |
0x0BB9 | Lvl Curve |
0x0BBA | BC Initial |
0x0BBB | BC Level |
0x0BBC | BC Empty |
0x0BBD | BC Full |
0x0BBE | BC Echo Missing |
0x0BBF | BC Echo Lost |
0x0BC0 | BC No Fiducial |
0x0BC1 | BC Restart |
0x0BC2 | Std Echo Rejection |
0x0BC3 | Custom Echo Rejection |
0x0BC4 | Echo Reference |
0x0BC5 | Reset Max/Min Temps |
0x0026 | Unknown |
0x0027 |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
220 | 4099 | read_Earlier_HistEvent |
Variable Write Command List
None