Loading…
Loading…
Variable Name: EchoRejectState
Variable ID: 0x46F8
Variable Label: Echo Reject State
Variable Help: Off - Rejection curve is not used (squelches Echo Reject Invalid warning). Disabled – Present Rejection Curve is not being used. Often it has been rendered Invalid due to configuration changes to Dielectric, Turbulence, Foam, Sensitivity or Tank Height. Re-run Echo Rejection. Enabled - Echo Rejection Curve has been run successfully and is in use.
Variable Handling: R/W
Variable Class:
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | Off |
0x0001 | Disabled |
0x0002 | Enabled |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
171 | 49FC | read_echo_rejection_parameters |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
172 | 49FD | set_echo_rejection_parameters |