Variable Name: Algorithm

Variable ID: 0x4045

Variable Label: Target Algorithm

Variable Help: The method used to select the echo pulse used for the level measurement. Largest selects the largest echo. First selects the first echo above the detection threshold. Height/Distance selects the echo with the largest height divided by distance ratio.

Variable Handling: R/W

Variable Class: Device

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Largest Amplitude
0x0001 First Target
0x0002 Amplitude/Distance
0x0003 Algorithm 4

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
179 4103 read_Algorithm

Variable Write Command List

Command Number Command ID Command Name
180 4104 set_Algorithm