Variable Name: Factory_Param5

Variable ID: 0x48E7

Variable Label: Targ Thresh Value

Variable Help: Threshold for detecting target. Default setting is suitable for most installations. Refer to I & O manual before adjusting.

Variable Handling: R/W

Variable Class: Correction

Variable Size: 4

Variable DataType: Float

Variable Display Format: |en|.0f

Variable Edit Format: |en|.0f

Variable Unit:

Variable Max:

Variable Min:

Variable Read Command List

Command Number Command ID Command Name
215 49F6 read_Factory_Params

Variable Write Command List

Command Number Command ID Command Name
216 49F7 set_Factory_Params