Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success
0x0002 Invalid selection
0x0003 Value was too high
0x0004 Value was too low
0x0005 Too few data bytes received
0x0006 Field device specific error
0x0007 In write protect mode
0x0010 Access restricted
0x0020 Busy
0x0021 Delayed response initiated
0x0022 Delayed response running
0x0023 Delayed response dead
0x0024 Delayed response conflict
0x0040 Command not implemented

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 4150 read_cond_calibration_variables
130 4152 Read_Temperature_Offset
134 4155 Read_Flaw_Size
135 4156 Read_namur_sammelstatus
136 4157 Read_Initial_Operation
140 4159 Read_Initial_Conditions
142 415A Read_Date_of_Manufacture
144 415B Read_Product_Info
144 415B Read_Product_Info
144 415B Read_Product_Info
146 415C Read_Last_TAG
147 415D Read_Software_Hardware_Version
148 415E Read_temperature_kompensation_menu
150 4160 Read_Long_Time_Status
151 4161 Read_Time_Constant
153 4163 Read_calibrationinterval
156 4166 read_ph_calibration_variables_2
157 4167 Read_Temperaturkoeffizient
160 4169 Read_Calibration_and_measuring
160 4169 Read_Calibration_and_measuring
160 4169 Read_Calibration_and_measuring
160 4169 Read_Calibration_and_measuring
160 4169 Read_Calibration_and_measuring
160 4169 Read_Calibration_and_measuring
165 416D Read_var_temperature_reference
179 4172 Read_Lock_device
182 4174 Read_Read_Max_Values
182 4174 Read_Read_Max_Values
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
50 1052 read_device_variable_assignments

Variable Write Command List

None