Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success
0x0002 Invalid selection
0x0003 Value was too high
0x0004 Value was too low
0x0005 Too few data bytes received
0x0006 Field device specific error
0x0007 In write protect mode
0x0010 Access restricted
0x0020 Busy
0x0021 Delayed response initiated
0x0022 Delayed response running
0x0023 Delayed response dead
0x0024 Delayed response conflict
0x0040 Command not implemented

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
130 41D9 read_device_variable_state
132 41DB read_device_variable_output_channel_setup
132 41DB read_device_variable_output_channel_setup
138 41DD READ_PRODUCTION_DATA
139 41DE READ_Advanced
150 41E0 READ_Conductivity_Status
151 41E1 Read_Capabilities
152 41E2 Read_Supported_Status_Mask
153 41E3 Read_ConductivitySensorInformation
154 41E5 Read_DeviceVariableRangeandLabelCapabilities
155 41E6 Read_ConductivityDeviceVariables
157 41E7 Read_Range_Hardware_Range
157 41E7 Read_Range_Hardware_Range
157 41E7 Read_Range_Hardware_Range
157 41E7 Read_Range_Hardware_Range
158 41E9 Read_Range_Output_Zoom
158 41E9 Read_Range_Output_Zoom
158 41E9 Read_Range_Output_Zoom
158 41E9 Read_Range_Output_Zoom
158 41E9 Read_Range_Output_Zoom
158 41E9 Read_Range_Output_Zoom
158 41E9 Read_Range_Output_Zoom
158 41E9 Read_Range_Output_Zoom
158 41E9 Read_Range_Output_Zoom
159 41EC Read_Range_Temperature_Compensation
159 41EC Read_Range_Temperature_Compensation
159 41EC Read_Range_Temperature_Compensation
159 41EC Read_Range_Temperature_Compensation
160 41EE Read_Range_Conductivity_Medium_Label
160 41EE Read_Range_Conductivity_Medium_Label
160 41EE Read_Range_Conductivity_Medium_Label
160 41EE Read_Range_Conductivity_Medium_Label
160 41EE Read_Range_Conductivity_Medium_Label
161 41F0 Read_Range_Concentration_Table_Points
161 41F0 Read_Range_Concentration_Table_Points
161 41F0 Read_Range_Concentration_Table_Points
161 41F0 Read_Range_Concentration_Table_Points
161 41F0 Read_Range_Concentration_Table_Points
161 41F0 Read_Range_Concentration_Table_Points
161 41F0 Read_Range_Concentration_Table_Points
161 41F0 Read_Range_Concentration_Table_Points
162 4202 Read_Range_Concentration_Medium_Label
162 4202 Read_Range_Concentration_Medium_Label
162 4202 Read_Range_Concentration_Medium_Label
162 4202 Read_Range_Concentration_Medium_Label
163 4204 Read_Range_Forced_Status
163 4204 Read_Range_Forced_Status
163 4204 Read_Range_Forced_Status
163 4204 Read_Range_Forced_Status
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
50 1052 read_device_variable_assignments

Variable Write Command List

None