Loading…
Loading…
Variable Name: lpFreq
Variable ID: 0x40B3
Variable Label: LP Filter
Variable Help: If the low pass filter is set to LOW, signals on high spectrum lines (from approx. line 30) are reduced. With max. 5 m high tanks, it can be set to LOW in order to suppress multiple reflections from below the tank bottom. Selection: LOW, HIGH (BM 702: 2.5/5/10/20 m) Default value: HIGH (SEr. 4.1.4)
Variable Handling: R/W
Variable Class: Correction
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | High (5.2 kHz) |
0x0001 | Low (1.5 kHz) |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
132 | 40AE | read_user_data_enums |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
133 | 40C6 | write_user_data_enums |