Variable Name: lpFreq

Variable ID: 0x40B3

Variable Label: LP Filter

Variable Help: If the low pass filter is set to LOW, signals on high spectrum lines (from approx. line 30) are reduced. With max. 5 m high tanks, it can be set to LOW in order to suppress multiple reflections from below the tank bottom. Selection: LOW, HIGH (BM 702: 2.5/5/10/20 m) Default value: HIGH (SEr. 4.1.4)

Variable Handling: R/W

Variable Class: Correction

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 High (5.2 kHz)
0x0001 Low (1.5 kHz)

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A