Variable Name: hdeFunc
Variable ID: 0x40B5
Variable Label: BD Detect
Variable Help: To activate the block distance (overfill) detector: So long as a significant signal is detected within the block distance, the measured value is "held" at the block distance limit. This avoids any possibility of the measured value skipping to a multiple reflection should the level rise into the block distance range. The block distance should have a value that is at least equal to that specified in help text for "Block distance" as a recommendation! Informational status bit "Tank overfilled" indicates when the block distance detector is active. If the measured value skips (e.g. contamination of the antenna) erroneously to the block distance limit, the "BD-Detect" can be deactivated. (Fct. 3.5.6)
Variable Handling: R/W
Variable Class: Correction
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | No |
0x0001 | Yes |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
132 | 40AE | read_user_data_enums |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
133 | 40C6 | write_user_data_enums |