Loading…

Variable Name: standardized_status_0_Ph

Variable ID: 0x4003

Variable Label: AO fixed

Variable Help: Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Simulation active
0x0002 Non-Volatile memory failure
0x0004 Volatile memory error
0x0008 Watchdog reset executed
0x0010 Voltage conditions out of range
0x0020 Environmental conditions out of range
0x0040 Electronic failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

None

Variable Write Command List

None