Loading…
Loading…
Variable Name: device_specific_status_2
Variable ID: 0x102D
Variable Label: Gate Array Error 2
Variable Help: Field Device Specific Status Byte 3- Data that has Field Device status information relating to: failures / warnings / status of process's.
Variable Handling: R
Variable Class: Dynamic | Diagnostic | Device
Variable Size: 1
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x0001 | ASIC circuit reference (T3): T3 Minimum value under |
0x0002 | ASIC circuit reference (T3): T3 Maximum value over |
0x0004 | Not used |
0x0008 | Not used |
0x0010 | Temp. of Sensor (T4, T7): T4,T7 Minimum value under |
0x0020 | Temp. of Sensor (T4, T7): T4,T7 Maximum value over |
0x0040 | Temp. of Sensor (T4, T7): Minimum value < \ |
0x0080 | Input Decoder error |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
48 | 1043 | read_additional_device_status |
Variable Write Command List
None