Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 Analog output 1 and its digital representation are outside the operating range limits, and not responding to input
0x0008 Analog output 1 and its digital representation are in fixed mode, and not responsive to input changes
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
129 411F ReadMDFlag
166 4120 Read_Status_Mask_LDMD_Mode
173 4130 Read_Valve_Travel_Cycle_Count
175 4137 Read_PST_Info
177 413C Read_ActRatio_Info
179 4147 Read_Spool_Info
181 4155 Read_Trend_Table
184 4158 Read_Trend_State
187 415D Read_Stick_Values
189 4163 Read_Leak_Values
194 4179 Read_Worst_Case
195 4180 Read_Supply_Pressure
197 418A Read_Friction_Settings
200 418C Read_Misc_cmd
202 418E Read_Status_cmd
204 4190 Read_Pressure
205 4191 Read_Revisions
212 4192 Read_Charact_cmd
218 4194 Read_Position_Alrt_cmd
220 4196 Read_Units
222 4198 Read_Temp_History
223 4199 Read_Hours
224 419A Read_Calibration_cmd
226 419C Read_Cal_Loop_cmd
228 419E Read_Error_Hist_cmd
230 41A0 Read_Actuator_cmd
232 41A2 Read_System_cmd
234 41A4 Read_Valve_cmd
236 41A6 Read_Valve_Trim_cmd
238 41A8 Read_Tuning_cmd
240 41AA ReadLimitsChar
244 41AC Read_Charact_cmd2
246 41AE Read_Config_cmd
252 41B0 ReadSigData
253 41B1 Read_SigSettings
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
33 1054 read_device_variables
48 1043 read_additional_device_status

Variable Write Command List

None