Loading…

Variable Name: EH_Second

Variable ID: 0x409B

Variable Label: 2nd event

Variable Help: This is part of the event history.

Variable Handling: R

Variable Class: InputBlock

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Initializing
0x0001 Factory Reset State
0x0002 Digital Command Mode
0x0003 Squawk Mode
0x0004 Jog Command Mode
0x0005 Signature In Progress
0x0006 Reserved
0x0007 Reserved
0x0008 Position Deviation
0x0009 Soft Stop Upper Limit
0x000A Soft Stop Lower Limit
0x000B Position Upper Limit
0x000C Position Lower Limit
0x000D MPC Active
0x000E Local Interface Disabled
0x000F Error History Reset
0x0010 Pneumatic Leak Warning
0x0011 Actuation Ratio Warning
0x0012 Pneumatic unable to Fail Safe
0x0013 Friction High Warning
0x0014 Friction Low Warning
0x0015 Friction Low Alarm
0x0016 Valve Cycles Warning
0x0017 Valve Travel Warning
0x0018 Stroke Cal in Progress
0x0019 Loop Cal in Progress
0x001A Pressure Cal in Progress
0x001B Analog Output Cal in Progress
0x001C Setting Inner Loop Offset
0x001D Reserved
0x001E Reserved
0x001F Reserved
0x0020 Temp High Warning
0x0021 Temp Low Warning
0x0022 Shunt Voltage Error
0x0023 Piezo Voltage Error
0x0024 Watch Dog Timeout
0x0025 NVRam Checksum Error
0x0026 Loss of Inter-PCB Comm
0x0027 Elect. Unable to Failsafe
0x0028 Supply Press Low Alarm
0x0029 Supply Press High Warn
0x002A Supply Press Low Warn
0x002B Port 1 OORange
0x002C Port 2 OORange
0x002D Port 1 Range < Min
0x002E Port 2 Range < Min
0x002F Pneumatic Leak Warning
0x0030 Pilot Relay Warning
0x0031 Pilot Relay Alarm
0x0032 Spool Cycles Warning
0x0033 Spool Travel Warning
0x0034 Hall Sensor Upper Pos
0x0035 Hall Sensor Lower Pos
0x0036 Reserved
0x0037 Reserved
0x0038 Feedback Range < Min
0x0039 0% Position OORange
0x003A 100% Position OORange
0x003B No Motion Time Out
0x003C Non-Settle Time Out
0x003D ILO Time Out
0x003E Jog Cal-Set 100% Pos
0x003F Reserved
0x0040 Command Loop Range < Min
0x0041 Command Loop OORange 100%
0x0042 Command Loop OORange 0%
0x0043 Analog Output Range < Min
0x0044 Reserved
0x0045 Reserved
0x0046 Reserved
0x0047 Reserved
0x0048 Pressure Sensor Board Present
0x0049 Analog Output Board Present
0x004A Pressure Control Locked
0x004B Pot Rotation Reversed
0x004C Reserved
0x004D Reserved
0x004E Reserved
0x004F Reserved

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
228 419E Read_Error_Hist_cmd

Variable Write Command List

None