Loading…

Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 PV Analog Channel Saturated
0x0008 PV Analog Channel Fixed
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
170 4000 read_index_parameter
167 41AF ReadSimulation
168 41B0 ReadAdvancedDiagnostics
173 41B1 ReadDisplayParameter
174 41B2 ReadMasterSetup
175 41B3 ReadActualDiagnostics
176 41B4 ReadLastDiagnostics
177 41B5 ReadHARTInfo
178 41B6 ReadActualDiagnosticsTimestamps
179 41B7 ReadDeviceIdentification2
182 41BA ReadDeviceIdentification1
184 41BC ReadDynamicValues
185 41BD ReadCurrentOutputSettings
186 41BE ReadMinMaxValues
187 41BF ReadHARTVariables
188 41C0 ReadLastDiagnosticsTimestamps
190 41C1 ReadSensorSettings
193 41C2 ReadCVDPolynomSettingsSensor1
194 41C3 ReadLocationInformation
196 1303 read_condensed_status_map
196 1303 read_condensed_status_map
196 1303 read_condensed_status_map
196 1303 read_condensed_status_map
198 41C4 read_diag_behav_mapping
198 41C4 read_diag_behav_mapping
198 41C4 read_diag_behav_mapping
198 41C4 read_diag_behav_mapping
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status

Variable Write Command List

None