Loading…

Variable Name: device_specific_status_2

Variable ID: 0x102D

Variable Label: Status Group 2

Variable Help: Field Device Specific Status Byte 3- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 402-Initialization active-Device temperature
0x0002 402-Initialization active-Sensor RJ
0x0004 410-Data transfer failed
0x0008 411-Up-/download active
0x0010 435-Linearization faulty-Sensor 1
0x0020 435-Linearization faulty
0x0040 435-Linearization faulty-Sensor RJ
0x0080 485-Process variable simulation active-Sensor 1

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 1043 read_additional_device_status

Variable Write Command List

None