Loading…

Variable Name: device_specific_status_5

Variable ID: 0x1030

Variable Label: Status Group 5

Variable Help: Field Device Specific Status Byte 6- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0002 140 Sensor signal asymmetrical -> Remedy information: 1. Check or replace sensor electronic module (ISEM) 2. If available: Check connection cable between sensor and transmitter 3. Replace sensor
0x0010 F082 Data storage inconsistent -> Remedy information: 1. Check module connections 2. Contact service
0x0040 C412 Processing download -> Remedy information: Download active, please wait
0x0080 913 Medium unsuitable -> Remedy information: 1. Check process conditions 2. Check electronic modules or sensor

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 1043 read_additional_device_status

Variable Write Command List

None