Loading…

Variable Name: device_specific_status_4

Variable ID: 0x102F

Variable Label: Status Group 4

Variable Help: Field Device Specific Status Byte 5- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 442 Frequency output faulty -> Remedy information: 1. Check process 2. Check frequency output settings
0x0002 443 Pulse output 1 faulty -> Remedy information: 1. Check process 2. Check pulse output settings
0x0004 C492 Frequency output simulation active -> Remedy information: Deactivate simulation frequency output
0x0008 C493 Pulse output simulation active -> Remedy information: Deactivate simulation pulse output
0x0010 C494 Switch output simulation active -> Remedy information: Deactivate simulation switch output
0x0040 C495 Diagnostic event simulation active -> Remedy information: Deactivate simulation

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 1043 read_additional_device_status

Variable Write Command List

None