Loading…

Variable Name: xmtr_specific_status_1

Variable ID: 0x0FB6

Variable Label: Status group 2

Variable Help: Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0080 A101 checksum error general reset & new calibr.required
0x0040 W103 initialising - please wait 
0x0020 W153 initialising - please wait 
0x0010 A1122 Current output 1 not calibrated 
0x0008 A2122 Current output 2 not calibrated 
0x0004 A171 electronics defect  
0x0002 A110 checksum error general reset & new calibr.required
0x0001 A160 checksum error general reset & new calibr.required

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 0FCE read_additional_transmitter_status

Variable Write Command List

None