Loading…

Variable Name: xmtr_specific_status_1

Variable ID: 0x0FB6

Variable Label: Status group 2

Variable Help: Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 121: No Values Analog Outp. Adjust Channel 1
0x0002 122: No Values Analog Outp. Adjust Channel 2
0x0004 613: Operating Mode Simulation Channel 1
0x0008 614: Operating Mode Simulation Channel 2
0x0010 501: Selection Type Of Sensor 1
0x0020 502: Selection Type Of Sensor 2
0x0040 601: Linearization Channel 1 Failure
0x0080 602: Linearization Channel 2 Failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 0FCE read_additional_transmitter_status

Variable Write Command List

None