Loading…

Variable Name: device_specific_status_1

Variable ID: 0x102C

Variable Label: Status Group 1

Variable Help: Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0002 C485 Process variable simulation active -> Remedy information: Deactivate simulation
0x0004 M287 Memory content inconsistent -> Remedy information: 1. Restart device 2. Contact service

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 1043 read_additional_device_status

Variable Write Command List

None