Loading…
Loading…
Variable Name: device_specific_status_0
Variable ID: 0x102B
Variable Label: Status Group 0
Variable Help: Field Device Specific Status Byte 1- Data that has Field Device status information relating to: failures / warnings / status of process's.
Variable Handling: R
Variable Class: Dynamic | Diagnostic | Device
Variable Size: 1
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x0002 | F282 Data storage inconsistent -> Remedy information: 1. Restart device 2. Contact service |
0x0004 | F283 Memory content inconsistent -> Remedy information: 1. Transfer data or reset device 2. Contact service |
0x0010 | C431 Trim required -> Remedy information: Carry out trim |
0x0080 | C491 Current output simulation active -> Remedy information: Deactivate simulation |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
48 | 1043 | read_additional_device_status |
Variable Write Command List
None