Variable Name: device_specific_status_24

Variable ID: 0x103B

Variable Label: Status Group 24

Variable Help: Field Device Specific Status Byte 25- Data that has Field Device status information relating to: failures / warnings / status of process's.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Unknown Error
0x0002 Basic Initialization required
0x0004 Unknown Error
0x0008 Clean mirror
0x0010 Unknown Error
0x0020 Configure gas again
0x0040 Terminal voltage is not ok
0x0080 Difference beteween ICOM and 4-20mA interface at the PIR7X00 sensor

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
48 1043 read_additional_device_status

Variable Write Command List