Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success
0x0002 Invalid selection
0x0003 Value was too high
0x0004 Value was too low
0x0005 Too few data bytes received
0x0006 Field device specific error
0x0007 In write protect mode
0x0010 Access restricted
0x0020 Busy
0x0021 Delayed response initiated
0x0022 Delayed response running
0x0023 Delayed response dead
0x0024 Delayed response conflict
0x0040 Command not implemented

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
131 4000 readSensorInformation
133 1430 read_sensor_analytical_data
137 4017 readCalInterval
146 4023 readSTest
147 4028 read_status
148 4046 readTransmitterSpecificOptions
148 4046 readTransmitterSpecificOptions
150 4052 readSensorId
189 4057 StartSTest
203 4058 readSDiagnostics
212 405D readSTestStatus
144 4060 readSensorLock
153 4065 changeSensorStatus
130 141E read_transmitter_info
130 141E read_transmitter_info
134 4076 readDate
136 4081 read_analog_output_config
154 4093 set_analog_output_temporary_limits
249 409F read_analog_offset
151 40A5 readLogger
217 40B5 cReadFieldbusInformation
218 40B6 cReadFastResponse
220 40BA cReadProfiAddr
235 40C0 cReadCategory
237 40CF cReadSilLock
238 40D3 cReadDecimalPointSet
243 40E2 cReadLang
245 40E7 cReadFunKey
247 40ED cReadDisplaySet
138 40F0 readAlarmDeadBands
155 4104 readAlarmLevelsReduced
156 410D readAlarmLevelsAscii
201 4132 readAlarmLimits
202 4137 readAlarmBandLimits
149 4141 read_calib
251 414A read_last_cal_params
132 426A read_meas_gas_unit_info
139 4276 read_gas_unit_range
140 4279 read_calgas_unit
141 4280 read_gas_name
142 428B read_range_information
143 428F read_unit_name
143 428F read_unit_name
157 4294 read_calgas_name
161 4299 read_testgasLel_ascii
158 429B read_calunit0_name
159 429D read_range_information_temp
200 42AB read_unit_name_temp
210 42AC read_testgas_conc_temp
211 42AD read_configured_testgas_conc_info
213 42AE read_testgasunit_name_temp
216 42AF read_gas_lel_Limits
128 1418 read_PV_in_units
135 42E0 read_transmitter_temp
152 42E2 read_sensor_temp
204 42E4 read_error_status
205 42F9 read_error_history
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status

Variable Write Command List

None