Loading…

Variable Name: MinChord

Variable ID: 0x43F7

Variable Label: Minimum Operating Chords

Variable Help: The minimum number of operating chords for a valid measurement. If the number of operating chords is less than this value, then the too few operating chords status is set. The range of values and default value are dependent upon the meter device number.

Variable Handling: R/W

Variable Class:

Variable Size: 1

Variable DataType: Unsigned

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
185 4402 ReadAcquisitionConfiguration

Variable Write Command List

Command Number Command ID Command Name
184 43F0 WriteAcquisitionConfiguration