Loading…
Loading…
Variable Name: HCH_Method
Variable ID: 0x4485
Variable Label: AGA8 Method
Variable Help: Selects the AGA8 calculation method. If the calculations are to be performed externally, then the base-condition pressure and temperature values must be specified and the flow-condition pressure and temperature values must be fixed or live and the calculation results must be specified.
Variable Handling: R/W
Variable Class:
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | External |
0x0001 | Gross Method 1 |
0x0002 | Gross Method 2 |
0x0003 | Detailed Method |
0x0004 | None |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
212 | 4490 | ReadAGA8MethodConfiguration |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
211 | 4484 | WriteAGA8MethodConfiguration |