Variable Name: GasPropertiesSrcSelGCAlarm
Variable ID: 0x4482
Variable Label: Data Source in Alarm Condition
Variable Help: Selects the gas property data source to use when the GC is in an alarm condition. Available user selections are Last good value (0) or Fixed value (1). If Fixed value is selected, the meter will start using the fixed gas composition stored in the meter. If Last good value is selected, the meter will use the last gas composition collected from the GC before the GC started to report alarms. When Last good value is selected, the in-use gas property data is not updated with the invalid GC-read gas property data. When Fixed value is used, the in-use gas property data is updated with the fixed gas property data.
Variable Handling: R/W
Variable Class:
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | Last Good Value |
0x0001 | Fixed Value |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
210 | 4483 | ReadGasChromatographConfiguration |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
209 | 4477 | WriteGasChromatographConfiguration |