Loading…

Variable Name: CalMethod

Variable ID: 0x43FB

Variable Label: Flow Calibration Method

Variable Help: Selects the wet calibration method to apply to the velocity measurement. If set to "None" then the wet calibration has the same value as the dry calibration. If set to "Polynomial Coefficients" then the "C" calibration coefficients are applied. If set to "Piece-Wise Linear" then the piece-wise linearization flow rate and meter factor parameters are used to calculate the meter factor to be applied.

Variable Handling: R/W

Variable Class:

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 None
0x0001 Polynomial
0x0002 Piece-Wise Linear

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
185 4402 ReadAcquisitionConfiguration

Variable Write Command List

Command Number Command ID Command Name
184 43F0 WriteAcquisitionConfiguration