Variable Name: IsDI1ForCalStateGated
Variable ID: 0x4039
Variable Label: Calibration Gating
Variable Help: This point specifies the calibration gating for digital input 1 when it is configured via IsDI1UsedForCal) for use in synchronizing a calibration. When FALSE (0), the calibration is started/stopped via an inactive->active edge; when TRUE (1), the calibration is started via an inactive->active state change and stopped via an active->inactive state change. The active edge/state is specified via the IsDI1ForCalActiveLow data point.
Variable Handling: R/W
Variable Class:
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | Digital Input 1 Calibrate Edge Gated |
0x0001 | Digital Input 1 Calibrate State Gated |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
143 | 40F1 | ReadDigitalInputConfiguration |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
142 | 40F0 | WriteDigitalInputConfiguration |